Products

Series 430

0.3” O.D. AC LVDTs

The Series 0430, 0.3” O.D. miniature AC LVDTs offer precision linear displacement measurements for applications with strokes from +/-0.01″ to +/-1.0″. The small size of these transducers make them ideal for weight critical applications and placement in tight spaces. The core is light enough to be used in systems with low driving forces or high accelerations without adversely affecting the system performance.

Key Features

  • Ranges from ±0.010″ to 1.0″
  • 0.3” Outer Diameter
  • Non-linearity <±0.25%
  • Carbon Steel Construction
  • Lightweight Core Assembly
  • Low Temperature Coefficient

TRANSDUCER SPECIFICATIONS

MODEL FULL STROKE ± Inches (mm) * STROKE OVERTRAVEL, Min. Inches (mm) BODY LENGTH, L, Inches (mm) CORE P/N CORE LENGTH, Lc, Inches (mm) CORE MASS Grams INPUT IMPEDANCE Ohms DC INPUT RESISTANCE Ohms OUTPUT IMPEDANCE Ohms PHASE ANGLE Degrees
0431-0000 0.010 (0.254) 0.150 (3.81) 0.85 (21.59) C005-0158 0.45 (11.43) 0.14 149 24 98 -6
0432-0000 0.025 (0.635) 0.150 (3.81) 0.85 (21.59 C005-0158 0.45 (11.43) 0.14 149 24 98 -6
0433-0000 0.050 (1.27) 0.150 (3.81) 0.85 (21.59) C005-0158 0.45 (11.43) 0.14 149 24 98 -6
0434-0000 0.100 (2.54) 0.150 (3.81) 0.95 (24.13) C005-0157 0.55 (13.97) 0.17 318 42 152 -5
0435-0000 0.250 (6.35) 0.600 (15.24) 2.40 (60.96) C005-0155 1.19 (30.23) 0.40 133 15 170 0
0436-0000 0.500 (12.7) 0.500 (12.7) 3.10 (78.74) C005-0155 1.19 (30.23) 0.40 139 18 124 0
0437-0000 1.000 (25.4) 0.500 (12.7) 4.30 (109.22) C005-0155 1.19 (30.23) 0.40 245 31 190 5

*Monotonic output voltage past each end of linear stroke.

(Specifications at reference frequency)

MODELS 0431-0000 0432-0000 0433-0000 0434-0000 0435-0000 0436-0000 0437-0000
NON-LINEARITY ≤ ± 0.25% FS (Best Fit Straight Line)
REFERENCE FREQUENCY 7.0kHz Sinusoidal Voltage Excitation
SENSITIVITY, Vin/IN/Vout ±10% 5.25 5.25 5.25 5.04 1.95 1.0 0.50
INPUT VOLTAGE 15 VRMS, Max.
NULL VOLTAGE 0.25% 0.3% 0.4% 0.8% 1% 1% 1%
ELECTRICAL CENTER, Ec 0.385 (9.78) 0.385 (9.78) 0.385 (9.78) 0.435 (11.05) 1.21 (30.73) 1.46 (37.08) 2.06 (52.32)
TEMPERATURE COEFFICIENTS ±0.003% FS/°F ±0.003% FS/°F ±0.0012 FS/°F ±0.0012 FS/°F ±0.0012 FS/°F ±0.0012 FS/°F ±0.0012 FS/°F
TEMPERATURE RANGE -67°F to +257°F (-55°C to +125°C) Operating-67°F to +275°F (-55°C to +135°C) Storage
OUTER HOUSING DOM 1018 Carbon Steel Housing.
BORE LINER Torlon Torlon Torlon St. St. 300 St. St. 300 St. St. 300 St. St. 300
CORE Chrome Plated Iron/Nickel Alloy

DIMENSIONAL DIAGRAM

0430_diagram

CORE OPTIONS

MODEL CORE, OPTION 0 CORE ASSEMBLY, OPTION 1
0431-0000_ C005-0158 A = 1.075 (27.31), C004-0211
0432-0000_ C005-0158 A = 1.075 (27.31), C004-0211
0433-0000_ C005-0158 A = 1.075 (27.31), C004-0211
0434-0000_ C005-0157 A = 1.575 (40.01), C004-0212
0435-0000_ C005-0155 A = 2.275 (57.79), C004-0213
0436-0000_ C005-0155 A = 2.775 (70.49), C004-0214
0437-0000_ C005-0155 A = 3.875 (98.43), C004-0215

SCHEMATIC

0430_schematic

The core is constructed from a soft, high permeability iron-nickel alloy. Non-magnetic stainless steel is used as the extension rod material. Core assemblies are sized for use over the maximum working range of the LVDT. The core is drilled at both ends with #72, shown above. Option 0, core only, should be used in applications when a separate extension rod is desirable. Option 1, core assembly, has a #4-40 thread screw brazed to the extension rod which is brazed to the appropriate core.

SERIES 430 MODIFIED FOR USE IN HIGH PRESSURE ENVIRONMENTS

The high pressure version of the Series 430 is suitable for operation in nonconductive and noncorrosive fluids or gasses at pressures up to 5,000 P.S.I. The vented housing eliminates pressure differentials between the environment and the transducer’s interior, allowing rapid and extreme pressure changes without damage or degradation in performance. Refer to the table on the previous page for core options.

MODEL STROKE ±Inches (mm)
0431-0001_ 0.010 (0.254)
0432-0001_ 0.025 (0.635)
0433-0001_ 0.050 (1.27)
0434-0001_ 0.100 (2.54)
0435-0001_ 0.250 (6.35)
0436-0001_ 0.500 (12.7)
0437-0001_ 1.000 (25.4)

0430_diagram_pressure

Note: All electrical and physical specifications are the same as the standard Series 430 LVDTs. 

SERIES 430 MODIFIED FOR USE IN HIGH TEMPERATURE ENVIRONMENTS

The high pressure version of the Series 430 is suitable for operation in nonconductive and noncorrosive fluids or gasses at pressures up to 5,000 P.S.I. The vented housing eliminates pressure differentials between the environment and the transducer’s interior, allowing rapid and extreme pressure changes without damage or degradation in performance. Refer to the table on the previous page for core options.

MODEL  STROKE ± Inches (mm) 
0431-0002_ 0.010 (0.254)
0432-0002_ 0.025 (0.635)
0433-0002_ 0.050 (1.27)
0434-0002_ 0.100 (2.54)
0435-0002_ 0.250 (6.35)
0436-0002_ 0.500 (12.7)
0437-0002_ 1.000 (25.4)

Note: All electrical and physical specifications are the same as the standard Series 430 LVDTs. 

CAD DRAWINGS

Download drawings from 3DContentCentral.com. (Account Required)

Download Now