Excellence in Linear and Angular Displacement
and Linear Velocity Transducers

Series 290

General Purpose AC LVDTs

  • Ranges from ±0.05” to 6.0”
  • Non-linearity ≤ 0.5%
  • High Input Impedance
  • 0.5” and 0.75” Outer Diameter

The Series 290 AC LVDTs are general purpose transducers designed to operate in most industrial environments. All units are terminated in 6 leads, allowing convenient connection to most conditioning electronics.

Specifications Electrical

MODELLINEAR RANGE ±Inches (mm)REFERENCE FREQUENCYSENSITIVITY V/in./VINPUT IMPEDANCE OhmsOUTPUT IMPEDANCE OhmsPHASE ANGLE UNCOMPENSATEDFREQUENCY FOR ZERO PHASE SHIFTMAXIMUM EXCITATION
0290-00000.050 (1.27)10.0 KHz2.61550860-3.6°7.0 KHz1.0 V.A.
0291-00000.100 (2.54)5.0 KHz3.974017905.0 KHz1.0 V.A.
0292-00000.250 (6.35)2.4 KHz1.621008139.3°30 KHz1.0 V.A.
0293-00000.500 (12.7)2.4 KHz0.7580015611°10 KHz1.0 V.A.
0294-00001.00 (25.4)2.4 KHz0.614581949.3°9.3 KHz1.0 V.A.
0295-00002.00 (50.8)2.4 KHz0.4120505206.4 KHz1.0 V.A.
0296-00003.00 (76.2)2.4 KHz0.23136035614°6.8 KHz1.0 V.A.

Notes:

  1. Electrical specifications are based on energizing the primary coil with the specified excitation frequency.
  2. Nominal values are given for sensitivity.
  3. Operating Temperature -50°F to +250°F (-46°C to +121°C)
 

Specifications - Mechanical

MODELHOUSING LENGTH A Inches (mm)CORE LENGTH B Inches (mm)ELECTRICAL CENTER C Inches (mm)INNER SLEEVE MATERIALTOTAL NET WEIGHT W/0 CORE GramsCORE NET WEIGHT GramsCORE PART NUMBERLEAD LENGTH, GAUGE
0290-00000.88 (22.3)0.56 (14.2)0.34 (8.64)PHENOLIC140.4C005-00037” AWG #30
0291-00001.06 (27.0)0.81 (20.6)0.46 (11.7)PHENOLIC170.7C005-00077” AWG #30
0292-00003.21 (81.5)1.75 (44.5)1.40 (35.6)S.S.562.5C005-005418” AWG #26
0293-00003.71 (94.2)1.50 (38.1)1.65 (41.9)S.S.652.0C005-005518” AWG #26
0294-00004.71 (120)1.75 (44.5)2.15 (54.6)S.S.742.5C005-005418” AWG #26
0295-00008.21 (209)2.50 (63.5)3.90 (99.1)S.S.1163.6C005-005618” AWG #26
0296-000010.52 (267)2.00 (50.8)5.30 (134)S.S.1362.8C005-004818” AWG #26

For technical drawings, and more information please download the Spec Sheet PDF. You will need to have Adobe Reader installed. Please feel free to contact us directly if you need assistance with any of our product specs or require information about non-standard items.

Dimensional Diagram

Schematic

Core Extension Rods (Sold Separately)

The recommended core extension rods are made of nonmagnetic stainless steel and are sized to allow the transducers to operate over their full range. Extension rods from models with longer strokes may be used to facilitate installation. Using extension rods shorter than recommended may reduce the LVDT’s usable measurement range.

 
MODELLENGTH L (mm)CORE EXTENSION ROD
0290-00002.00 (50.8)C006-0056
0291-00002.00 (50.8)C006-0056
0292-00002.00 (50.8)C006-0056
0293-00003.25 (82.6)C006-0057
0294-00005.25 (133)C006-0058
0295-00008.40 (213)C006-0059
0296-00008.40 (213)C006-0059

Related Products and Accessories